Additional Information

Site Information

 Loading... Please wait...
  • Image 1

JRSBRT 4.3, p. 191-201

$40.00
Quantity:

Product Description

Prospective evaluation of target and spinal cord motion and dosimetric changes with respiration in spinal stereotactic body radiation therapy utilizing 4-D CT
Xin Wang, Amol J. Ghia, Zhongxiang Zhao, Jinzhong Yang, Dershan Luo, Tina M. Briere, Ramiro Pino, Jing Li, Mary F. Mcaleer, David C. Weksberg, Eric L. Chang, Paul D. Brown and James N. Yang

Purpose: To assess the dosimetric effects of respiratory motion on the target and spinal cord in spinal stereotactic body radiation therapy (SBRT).

Methods and materials: Thirty patients with 33 lesions were enrolled on a prospective clinical protocol and simulated with both free-breathing and four-dimensional (4-D) computed tomography (CT). We studied the target motion using 4-D data (10 phases) by registering a secondary image dataset (phase 1 to 9) to a primary image dataset (phase 0) and analyzing the displacement in both translational and rotational directions. The study of dosimetric impacts from respiration includes both the effect of potential target and spinal cord motion and anatomic changes in the beam path. A clinical step-and-shoot IMRT plan generated on the free-breathing CT was copied to the 4-D datasets to evaluate the difference in the dose-volume histogram of target and normal tissues in each phase of a breathing cycle.

Results: Twenty three lesions had no motion in a breathing cycle; four lesions had anterior-posterior motion ≤ 0.2 mm; two lesions had lateral motion ≤ 0.2 mm; and eight lesions had superior-inferior motion, most ≤ 0.2 mm with the worst at 0.6 mm. The difference of maximum dose to 0.01 cm3 of spinal cord in different phases of a breathing cycle was within 20 cGy in worst case. Target volumes that received the prescription dose (V100) varied little, with deviations of V100 of each phase from the average CT < 1% in most cases. Only when lesions were close to the diaphragm (e.g., at T11) did the V100 deviate by about 7% in the worst case scenario. However, this was caused by a small dose difference of 20 cGy to part of the target volume.

Conclusions: Breathing induced target and spinal cord motion is negligible compared with other setup uncertainties. Dose calculation using averaged or free-breathing CT is reliable when posterior beams are used.

Keywords: spinal SBRT, respiratory motion, 4-D CT

After payment has been processed for your order of a digital copy (PDF) of this article, you will see a download link on your completed order page and also receive an email containing a download link. The links, which will enable you to download one copy of the article, will expire after 24 hours.

Find Similar Products by Category